1 # Sample multimon configuration file
2 #
3 # This file is not required.  Without it, multimon will use the default
4 # field layout.
5 #
6 # Temperature selection
7
8 # Pick "TEMPC" for Celsius or "TEMPF" for Fahrenheit.  This will override
9 # the --enable-celsius setting from the compile.  UPSTEMP (below) will 
10 # use this setting by default.
11
12 TEMPC
13
14 # Format:
15 # FIELD <variable> "<field name>" "<field suffix>"
16 #
17 # <variable> is either a word from the UPS protocol like battchg (see the
18 # table in src/cgi/upsfetch.c) or a special word in uppercase.  
19 #
20 # Special words are:
21 # MODEL    - Show the model name for this system in cyan
22 #
23 # STATUS   - Parse the status for this system using the appropriate color
24 #
25 # UPSTEMP and AMBTEMP use the default scale.  This is set to C if you use
26 # --enable-celsius at compile time *or* if you use "TEMPC" above.
27 #
28 # UPSTEMP  - Show the UPS temperature in the default scale (suffix ignored)
29 # AMBTEMP  - Show the ambient temperature in the default scale (suffix ignored)
30 #
31 # UPSTEMPC - Show the UPS temperature in degrees C (suffix ignored)
32 # UPSTEMPF - Show the UPS temperature in degrees F (suffix ignored)
33 # AMBTEMPC - Show the ambient temperature in degrees C (suffix ignored)
34 # AMBTEMPF - Show the ambient temperature in degrees F (suffix ignored)
35
36 # They're called "special" since they actually understand the content
37 # being printed and do other things based on what's in there.
38
39 # <field name> is what you'd like this column to be called on the page.
40 # Remember that this is HTML, so you can actually embed markup in here.
41 # This means you can even include images here.  You can include quotes
42 # (and backslashes!) in the string by escaping them with a backslash (\).
43
44 # <field suffix> is typically something like % or VAC.  It's useful if
45 # you want to convey the units that apply to a value.
46 #
47 # Example config
48
49 FIELD SYSTEM "System" ""
50 FIELD MODEL "Model" ""
51 FIELD STATUS "Status" ""
52 FIELD battpct "Battery Chg" "%"
53 FIELD utility "Utility" "VAC"
54 FIELD loadpct "UPS Load" "%"
55 FIELD UPSTEMP "UPS Temp" ""
56 FIELD runtime "Batt. Run Time" "min."
57 FIELD DATA   "Data" "All data"
58
59 # These are only useful if you have a Smart-UPS model with the Measure-UPS II
60 # measurement card.  No other models presently support these features.
61