config BITBANGMII bool "Bit-banged ethernet MII management channel support" config MV88E6352_SWITCH bool "Marvell 88E6352 switch support" menuconfig PHYLIB bool "Ethernet PHY (physical media interface) support" help Enable Ethernet PHY (physical media interface) support. if PHYLIB config MV88E61XX_SWITCH bool "Marvel MV88E61xx Ethernet switch PHY support." if MV88E61XX_SWITCH config MV88E61XX_CPU_PORT int "CPU Port" config MV88E61XX_PHY_PORTS hex "Bitmask of PHY Ports" config MV88E61XX_FIXED_PORTS hex "Bitmask of PHYless serdes Ports" endif # MV88E61XX_SWITCH config PHYLIB_10G bool "Generic 10G PHY support" config PHY_AQUANTIA bool "Aquantia Ethernet PHYs support" config PHY_ATHEROS bool "Atheros Ethernet PHYs support" config PHY_BROADCOM bool "Broadcom Ethernet PHYs support" config PHY_CORTINA bool "Cortina Ethernet PHYs support" config PHY_DAVICOM bool "Davicom Ethernet PHYs support" config PHY_ET1011C bool "LSI TruePHY ET1011C support" config PHY_LXT bool "LXT971 Ethernet PHY support" config PHY_MARVELL bool "Marvell Ethernet PHYs support" config PHY_MICREL bool "Micrel Ethernet PHYs support" help Enable support for the GbE PHYs manufactured by Micrel (now a part of Microchip). This includes drivers for the KSZ804, KSZ8031, KSZ8051, KSZ8081, KSZ8895, KSZ886x, KSZ8721 either/or KSZ9021 (see the "Micrel KSZ9021 family support" config option for details), and KSZ9031 (if configured). if PHY_MICREL config PHY_MICREL_KSZ9021 bool "Micrel KSZ9021 family support" select PHY_GIGE help Enable support for the Micrel KSZ9021 GbE PHY family. If enabled, the extended register read/write for KSZ9021 PHYs is supported through the 'mdio' command and any RGMII signal delays configured in the device tree will be applied to the PHY during initialisation. Note that the KSZ9021 uses the same part number os the KSZ8921BL, so enabling this option disables support for the KSZ8721BL. config PHY_MICREL_KSZ9031 bool "Micrel KSZ9031 family support" select PHY_GIGE help Enable support for the Micrel KSZ9031 GbE PHY family. If enabled, the extended register read/write for KSZ9021 PHYs is supported through the 'mdio' command and any RGMII signal delays configured in the device tree will be applied to the PHY during initialisatioin. endif # PHY_MICREL config PHY_MSCC bool "Microsemi Corp Ethernet PHYs support" config PHY_NATSEMI bool "National Semiconductor Ethernet PHYs support" config PHY_REALTEK bool "Realtek Ethernet PHYs support" config RTL8211X_PHY_FORCE_MASTER bool "Ethernet PHY RTL8211x: force 1000BASE-T master mode" depends on PHY_REALTEK help Force master mode for 1000BASE-T on RTl8211x PHYs (except for RTL8211F). This can work around link stability and data corruption issues on gigabit links which can occur in slave mode on certain PHYs, e.g. on the RTL8211C(L). Please note that two directly connected devices (i.e. via crossover cable) will not be able to establish a link between each other if they both force master mode. Multiple devices forcing master mode when connected by a network switch do not pose a problem as the switch configures its affected ports into slave mode. This option only affects gigabit links. If you must establish a direct connection between two devices which both force master mode, try forcing the link speed to 100MBit/s. If unsure, say N. config PHY_SMSC bool "Microchip(SMSC) Ethernet PHYs support" config PHY_TERANETICS bool "Teranetics Ethernet PHYs support" config PHY_TI bool "Texas Instruments Ethernet PHYs support" config PHY_VITESSE bool "Vitesse Ethernet PHYs support" config PHY_XILINX bool "Xilinx Ethernet PHYs support" config PHY_FIXED bool "Fixed-Link PHY" depends on DM_ETH help Fixed PHY is used for having a 'fixed-link' to another MAC with a direct connection (MII, RGMII, ...). There is nothing like autoneogation and so on, the link is always up with fixed speed and fixed duplex-setting. More information: doc/device-tree-bindings/net/fixed-link.txt endif #PHYLIB