From 951bf19dae2198c7684e4bb3f1eae10ba60d3677 Mon Sep 17 00:00:00 2001 From: Peng Fan Date: Sun, 3 May 2020 22:19:50 +0800 Subject: [PATCH] thermal: imx_tmu: Check the TEMP range for iMX8MM On iMX8MM, the V flag in TRISTR register only reflect the state of SNSR value, not the calibrated TEMP value. So checking this flag is not reliable. Per IC suggestion, change to read the TEMP/AVG_TEMP directly and check whether it in valid range 10-125C. Signed-off-by: Ye Li Signed-off-by: Peng Fan --- drivers/thermal/imx_tmu.c | 14 +++++++++++--- 1 file changed, 11 insertions(+), 3 deletions(-) diff --git a/drivers/thermal/imx_tmu.c b/drivers/thermal/imx_tmu.c index 2a08d5085c..c577b0bd6c 100644 --- a/drivers/thermal/imx_tmu.c +++ b/drivers/thermal/imx_tmu.c @@ -106,16 +106,24 @@ static int read_temperature(struct udevice *dev, int *temp) ulong drv_data = dev_get_driver_data(dev); u32 val; u32 retry = 10; + u32 valid = 0; do { mdelay(100); retry--; - if (drv_data & FLAGS_VER2) + if (drv_data & FLAGS_VER2) { val = readl(&pdata->regs->regs_v2.tritsr); - else + /* + * Check if TEMP is in valid range, the V bit in TRITSR + * only reflects the RAW uncalibrated data + */ + valid = ((val & 0xff) < 10 || (val & 0xff) > 125) ? 0 : 1; + } else { val = readl(&pdata->regs->regs_v1.site[pdata->id].tritsr); - } while (!(val & 0x80000000) && retry > 0); + valid = val & 0x80000000; + } + } while (!valid && retry > 0); if (retry > 0) *temp = (val & 0xff) * 1000; -- 2.25.1