From 4cb06c72131e37fa9058707e11497cfd905b1a89 Mon Sep 17 00:00:00 2001 From: Hans Dedecker Date: Wed, 17 May 2017 14:49:17 +0200 Subject: [PATCH] ubus: increase ubus network interface dump timeout When netifd is being stressed (eg doing reconfig using multiple interfaces) ubus timeouts can be observed when invoking network interface dump. Increase the ubus timeout to 2000 msec similar to the service ubus timeout. Signed-off-by: Hans Dedecker --- ubus.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/ubus.c b/ubus.c index dd1075f..bcbe1e8 100644 --- a/ubus.c +++ b/ubus.c @@ -51,7 +51,7 @@ fw3_ubus_connect(void) if (ubus_lookup_id(ctx, "network.interface", &id)) goto out; - if (ubus_invoke(ctx, id, "dump", NULL, dump_cb, NULL, 500)) + if (ubus_invoke(ctx, id, "dump", NULL, dump_cb, NULL, 2000)) goto out; status = true; -- 2.25.1