--
-- Initiate firmware flash
--
- local step = tonumber(http.formvalue("step") or 1)
+ local step = tonumber(http.formvalue("step")) or 1
if step == 1 then
- if image_supported(image_tmp) then
+ local force = http.formvalue("force")
+ if image_supported(image_tmp) or force then
luci.template.render("admin_system/upgrade", {
checksum = image_checksum(image_tmp),
sha256ch = image_sha256_checksum(image_tmp),
storage = storage_size(),
size = (fs.stat(image_tmp, "size") or 0),
- keep = (not not http.formvalue("keep"))
+ keep = (not not http.formvalue("keep")),
+ force = (not not http.formvalue("force"))
})
else
fs.unlink(image_tmp)
image_invalid = true
})
end
+
--
-- Start sysupgrade flash
--
elseif step == 2 then
local keep = (http.formvalue("keep") == "1") and "" or "-n"
+ local force = (http.formvalue("force") == "1") and "" or "-F"
luci.template.render("admin_system/applyreboot", {
title = luci.i18n.translate("Flashing..."),
msg = luci.i18n.translate("The system is flashing now.<br /> DO NOT POWER OFF THE DEVICE!<br /> Wait a few minutes before you try to reconnect. It might be necessary to renew the address of your computer to reach the device again, depending on your settings."),
- addr = (#keep > 0) and "192.168.1.1" or nil
+ addr = (#keep > 0) and (#force > 0) and "192.168.1.1" or nil
})
- fork_exec("sleep 1; killall dropbear uhttpd; sleep 1; /sbin/sysupgrade %s %q" %{ keep, image_tmp })
+ fork_exec("sleep 1; killall dropbear uhttpd; sleep 1; /sbin/sysupgrade %s %s %q" %{ keep, force, image_tmp })
end
end
<form class="inline" method="post" action="<%=url('admin/system/flashops/backup')%>">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-value<% if not reset_avail then %> cbi-value-last<% end %>">
- <label class="cbi-value-title" for="image"><%:Download backup%>:</label>
+ <label class="cbi-value-title" for="image"><%:Download backup%></label>
<div class="cbi-value-field">
<input class="cbi-button cbi-button-action important" type="submit" name="backup" value="<%:Generate archive%>" />
</div>
<form class="inline" method="post" action="<%=url('admin/system/flashops/reset')%>">
<input type="hidden" name="token" value="<%=token%>" />
<div class="cbi-value cbi-value-last">
- <label class="cbi-value-title"><%:Reset to defaults%>:</label>
+ <label class="cbi-value-title"><%:Reset to defaults%></label>
<div class="cbi-value-field">
<input onclick="return confirm('<%:Really reset all changes?%>')" class="cbi-button cbi-button-reset" type="submit" name="reset" value="<%:Perform reset%>" />
</div>
<% end %>
<form class="inline" method="post" action="<%=url('admin/system/flashops/restore')%>" enctype="multipart/form-data">
<div class="cbi-value cbi-value-last">
- <label class="cbi-value-title" for="archive"><%:Restore backup%>:</label>
+ <label class="cbi-value-title" for="archive"><%:Restore backup%></label>
<div class="cbi-value-field">
<input type="hidden" name="token" value="<%=token%>" />
<input type="file" name="archive" id="archive" />
<div class="cbi-section-descr"><%:Upload a sysupgrade-compatible image here to replace the running firmware. Check "Keep settings" to retain the current configuration (requires a compatible firmware image).%></div>
<div class="cbi-section-node">
<div class="cbi-value">
- <label class="cbi-value-title" for="keep"><%:Keep settings%>:</label>
+ <label class="cbi-value-title" for="keep"><%:Keep settings%></label>
<div class="cbi-value-field">
<input type="checkbox" name="keep" id="keep" checked="checked" />
</div>
</div>
+ <% if image_invalid then %>
+ <div class="cbi-value">
+ <label class="cbi-value-title" for="force"><%:Force upgrade%></label>
+ <div class="cbi-value-field">
+ <input type="checkbox" name="force" id="force" />
+ </div>
+ <div class="cbi-section-error">
+ <%:The uploaded image file does not contain a supported format. Make sure that you choose the generic image format for your platform. %>
+ <%:Select 'Force upgrade' to flash the image even if the image format check fails. Use only if you are sure that the firmware is correct and meant for your device! %>
+ </div>
+ </div>
+ <% end %>
<div class="cbi-value cbi-value-last<% if image_invalid then %> cbi-value-error<% end %>">
- <label class="cbi-value-title" for="image"><%:Image%>:</label>
+ <label class="cbi-value-title" for="image"><%:Image%></label>
<div class="cbi-value-field">
<input type="file" name="image" id="image" />
<input type="submit" class="cbi-button cbi-button-action important" value="<%:Flash image...%>" />
</div>
</div>
</div>
- <% if image_invalid then %>
- <div class="cbi-section-error"><%:The uploaded image file does not contain a supported format. Make sure that you choose the generic image format for your platform. %></div>
- <% end %>
</form>
<% else %>
<div class="cbi-section-descr"><%:Sorry, there is no sysupgrade support present; a new firmware image must be flashed manually. Please refer to the wiki for device specific install instructions.%></div>
</p>
-<fieldset class="cbi-section">
+<div class="cbi-section">
<ul>
<li><%:Checksum%><br />
<%:MD5%>: <code><%=checksum%></code><br />
end
%></li>
<li><% if keep then %>
- <%:Configuration files will be kept.%>
+ <%:Configuration files will be kept%>
<% else %>
- <%:Note: Configuration files will be erased.%>
+ <%:Caution: Configuration files will be erased%>
<% end %></li>
+ <% if force then %>
+ <li>
+ <%:Caution: System upgrade will be forced%>
+ </li>
+ <% end %>
</ul>
-</fieldset>
+</div>
<div class="cbi-page-actions right">
<form class="inline" action="<%=REQUEST_URI%>" method="post">
<input type="hidden" name="token" value="<%=token%>" />
<input type="hidden" name="step" value="2" />
<input type="hidden" name="keep" value="<%=keep and "1" or ""%>" />
+ <input type="hidden" name="force" value="<%=force and "1" or ""%>" />
<input class="cbi-button cbi-button-reset" name="cancel" type="submit" value="<%:Cancel%>" />
<input class="cbi-button cbi-button-apply" type="submit" value="<%:Proceed%>" />
</form>