According to Data Manual(SPRS915P) of AM57x, TI QSPI controller on
DRA74(rev 1.1+)/DRA72 EVM can support up to 64MHz in MODE-0, whereas
MODE-3 is limited to 48MHz. Hence, switch to MODE-0 for better
throughput.
Signed-off-by: Vignesh R <vigneshr@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
Reviewed-by: Mugunthan V N <mugunthanvnm@ti.com>
Reviewed-by: Jagan Teki <jteki@openedev.com>
pinctrl-names = "default";
pinctrl-0 = <&qspi1_pins>;
- spi-max-frequency = <48000000>;
+ spi-max-frequency = <64000000>;
m25p80@0 {
compatible = "s25fl256s1","spi-flash";
- spi-max-frequency = <48000000>;
+ spi-max-frequency = <64000000>;
reg = <0>;
spi-tx-bus-width = <1>;
spi-rx-bus-width = <4>;
- spi-cpol;
- spi-cpha;
#address-cells = <1>;
#size-cells = <1>;
pinctrl-names = "default";
pinctrl-0 = <&qspi1_pins>;
- spi-max-frequency = <48000000>;
+ spi-max-frequency = <64000000>;
m25p80@0 {
compatible = "s25fl256s1","spi-flash";
- spi-max-frequency = <48000000>;
+ spi-max-frequency = <64000000>;
reg = <0>;
spi-tx-bus-width = <1>;
spi-rx-bus-width = <4>;
- spi-cpol;
- spi-cpha;
#address-cells = <1>;