On DRA72 EVM, cpsw slave1 is muxed with VIN2A, hence switch to cpsw
slave0 for ethernet. This is controlled by pcf gpio line. Add
appropriate mode-gpios DT entry so that driver can select the required
slave.
Signed-off-by: Vignesh R <vigneshr@ti.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
Reviewed-by: Mugunthan V N <mugunthanvnm@ti.com>
pinctrl-names = "default", "sleep";
pinctrl-0 = <&cpsw_default>;
pinctrl-1 = <&cpsw_sleep>;
+ mode-gpios = <&pcf_gpio_21 4 GPIO_ACTIVE_HIGH>;
};
&cpsw_emac1 {
pinctrl-names = "default", "sleep";
pinctrl-0 = <&davinci_mdio_default>;
pinctrl-1 = <&davinci_mdio_sleep>;
- active_slave = <1>;
};
&dcan1 {