net: phy: marvell: Fix problem with phy_reset() clearing BMCR
authorStefan Roese <sr@denx.de>
Wed, 10 Feb 2016 06:06:06 +0000 (07:06 +0100)
committerJoe Hershberger <joe.hershberger@ni.com>
Thu, 18 Feb 2016 17:32:03 +0000 (11:32 -0600)
With commit a058052c [net: phy: do not read configuration register on
reset], phy_reset() will clear the BMCR register. Resulting in bit 12
being cleared (A/N enable). This leads to autonegotiation link problems,
at least on the Marvell Armada ClearFog board. I suspect that other
boards using this driver will be affected as well.

At the of m88e1111s_config(), phy_reset() is called. This is not needed
for the PHY to load the changed configuration, as phy_reset() is called
a few lines before already. So lets call genphy_restart_aneg() here
instead to start the AN correctly.

Tested on clearfog.

Signed-off-by: Stefan Roese <sr@denx.de>
Cc: Stefan Agner <stefan@agner.ch>
Cc: Hao Zhang <hzhang@ti.com>
Cc: Michal Simek <monstr@monstr.eu>
Cc: Andy Fleming <afleming@gmail.com>
Cc: Joe Hershberger <joe.hershberger@ni.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
drivers/net/phy/marvell.c

index 6e3dc8537967a7deff790453c2b900acc70d53ef..b8b1157a0a4a19c9307bdf6a53135195407e08dd 100644 (file)
@@ -251,8 +251,7 @@ static int m88e1111s_config(struct phy_device *phydev)
        phy_reset(phydev);
 
        genphy_config_aneg(phydev);
-
-       phy_reset(phydev);
+       genphy_restart_aneg(phydev);
 
        return 0;
 }