Fix clock value initialisation for Exynos other than Exynos5 for hsi2c.
Signed-off-by: Piotr Wilczek <p.wilczek@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Cc: Minkyu Kang <mk7.kang@samsung.com>
Cc: Heiko Schocher <hs@denx.de>
unsigned int i = 0, utemp0 = 0, utemp1 = 0;
unsigned int t_ftl_cycle;
-#if defined CONFIG_EXYNOS5
+#if (defined CONFIG_EXYNOS4 || defined CONFIG_EXYNOS5)
clkin = get_i2c_clk();
+#else
+ clkin = get_PCLK();
#endif
/* FPCLK / FI2C =
* (CLK_DIV + 1) * (TSCLK_L + TSCLK_H + 2) + 8 + 2 * FLT_CYCLE