mmc: correct the HS400 initialization process
authorBOUGH CHEN <haibo.chen@nxp.com>
Tue, 26 Mar 2019 06:24:17 +0000 (06:24 +0000)
committerTom Rini <trini@konsulko.com>
Fri, 29 Mar 2019 14:53:18 +0000 (10:53 -0400)
After the commit b9a2a0e2e9c0 ("mmc: Add support for downgrading
HS200/HS400 to HS mode"), it add a parameter in mmc_set_card_speed()
which indicates that the HS200/HS400 to HS downgrade is happening.

During the HS400 initialization, first select to HS200, and config
the related clock rate, then downgrade to HS mode. So here also need
to config the downgrade value to be true for two reasons. First,
make sure in the function mmc_set_card_speed(), after switch to HS
mode, first config the clock rate, then read the EXT_CSD, avoid
receiving data of EXT_CSD in HS mode at 200MHz. Second, after issue
the MMC_CMD_SWITCH command, it need to wait a bit then switch bus
properties.

Test on i.MX8QM MEK board, some Micron eMMC will stuck in transfer
mode in this case, and USDHC will never get data transfer complete
status, cause the uboot hang.

Signed-off-by: Haibo Chen <haibo.chen@nxp.com>
Acked-by: Marek Vasut <marek.vasut@gmail.com>
drivers/mmc/mmc.c

index 89b255daf486759c74c8ae2c6c6e3f5369b4108a..456c1b4cc92321616141fa0feaebe5ebedb06e67 100644 (file)
@@ -1892,8 +1892,7 @@ static int mmc_select_hs400(struct mmc *mmc)
        }
 
        /* Set back to HS */
-       mmc_set_card_speed(mmc, MMC_HS, false);
-       mmc_set_clock(mmc, mmc_mode2freq(mmc, MMC_HS), false);
+       mmc_set_card_speed(mmc, MMC_HS, true);
 
        err = mmc_switch(mmc, EXT_CSD_CMD_SET_NORMAL, EXT_CSD_BUS_WIDTH,
                         EXT_CSD_BUS_WIDTH_8 | EXT_CSD_DDR_FLAG);