ppc4xx: Fix bug in I2C bootstrap values for Sequoia/Rainier
authorStefan Roese <sr@denx.de>
Mon, 15 Oct 2007 09:39:00 +0000 (11:39 +0200)
committerStefan Roese <sr@denx.de>
Mon, 15 Oct 2007 09:39:00 +0000 (11:39 +0200)
commite2e93442e558cf1500e92861f99713b2f045ea22
treead0949eac45569d114ff409ec59d485942e567ea
parent5a5958b7de70ae99f0e7cbd5c97ec1346e051587
ppc4xx: Fix bug in I2C bootstrap values for Sequoia/Rainier

The I2C bootstrap values that can be setup via the "bootstrap" command,
were setup incorrect regarding the generation of the internal sync PCI
clock. The values for PLB clock == 133MHz were slighly incorrect and the
values for PLB clock == 166MHz were totally incorrect. This could
lead to a hangup upon booting while PCI configuration scan.

This patch fixes this issue and configures valid PCI divisor values
for the sync PCI clock, with respect to the provided external async
PCI frequency.

Here the values of the formula in the chapter 14.2 "PCI clocking"
from the 440EPx users manual:

AsyncPCICLK - 1MHz <= SyncPCIClk <= (2 * AsyncPCIClk) - 1MHz

33MHz async PCI frequency:
PLB = 133:
=>      32 <= 44.3 <= 65        (div = 3)

PLB = 166:
=>      32 <= 55.3 <= 65        (div = 3)

66MHz async PCI frequency:
PLB = 133:
=>      65 <= 66.5 <= 132       (div = 2)

PLB = 166:
=>      65 <= 83 <= 132         (div = 2)

Signed-off-by: Stefan Roese <sr@denx.de>