board: ge: bx50v3: fix AR8033 reset timing issue
authorYung-Ching LIN <yungching0725@gmail.com>
Tue, 21 Feb 2017 01:56:55 +0000 (09:56 +0800)
committerJoe Hershberger <joe.hershberger@ni.com>
Sun, 26 Mar 2017 14:58:08 +0000 (09:58 -0500)
commitd42db168e68c6d7b87da673321ac25c657fb4a3a
treeb5f186a34d23d9adce854007fd02995ca3ba29e9
parent625cf507ff79412bb5fd2ded9a22365480d2c3bf
board: ge: bx50v3: fix AR8033 reset timing issue

Add the delay (10ms) to ensure the clock is stable and to meet the clock-to-reset(1ms) requirement recommended in the AR8033 datasheet

Signed-off-by: Ken Lin <yungching0725@gmail.com>
Reviewed-by: Stefano Babic <sbabic@denx.de>
Acked-by: Ian Ray <ian.ray@ge.com>
board/ge/bx50v3/bx50v3.c