arm: stm32mp: bsec: add permanent lock support in bsec driver
Add BSEC lock access (read / write) at 0xC0000000 offset of misc driver.
The write access only available for Trusted boot mode, based on new
SMC STM32_SMC_WRLOCK_OTP.
With the fuse command, the permanent lock status is accessed with
0x10000000 offset (0xC0000000 - 0x8000000 for OTP sense/program
divided by u32 size), for example:
Read lock status of fuse 57 (0x39)
STM32MP> fuse sense 0 0x10000039 1
Sensing bank 0:
Word 0x10000039:
00000000
Set permanent lock of fuse 57 (0x39)
STM32MP> fuse prog 0 0x10000039 1
Sensing bank 0:
Word 0x10000039:
00000000
WARNING: the OTP lock is updated only after reboot
WARING: Programming lock or fuses is an irreversible operation!
This may brick your system.
Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>
Acked-by: Patrice Chotard <patrice.chotard@st.com>