ppc/km/tegr1: support second localbus clock signal
authorHolger Brunck <holger.brunck@ch.abb.com>
Tue, 26 Nov 2019 18:09:00 +0000 (19:09 +0100)
committerPriyanka Jain <priyanka.jain@nxp.com>
Mon, 23 Dec 2019 08:36:47 +0000 (14:06 +0530)
commit4d4880086a413194a6fbeae0992f3ebf855ec878
treea45a7318b3c904b1d4ec6e9874463f50845e8550
parentc0912f9bbfb26dd03d189953678691b799d35b6e
ppc/km/tegr1: support second localbus clock signal

On kmtegr1 we have to specify the second localbus clock signal also
instead of using the default for our ppc 8309 boards.

Signed-off-by: Holger Brunck <holger.brunck@ch.abb.com>
Reviewed-by: Priyanka Jain <priyanka.jain@nxp.com>
CC: Priyanka Jain <priyanka.jain@nxp.com>
CC: Valentin Longchamp <valentin.longchamp@ch.abb.com>
include/configs/km/km-mpc8309.h
include/configs/kmtegr1.h