Robin Farine writes:
authorEric Andersen <andersen@codepoet.org>
Tue, 22 Jun 2004 10:18:30 +0000 (10:18 -0000)
committerEric Andersen <andersen@codepoet.org>
Tue, 22 Jun 2004 10:18:30 +0000 (10:18 -0000)
commit4872ed9737c1349aec2f41b1b8a905a9158da5c1
tree94b214366ce9fe141a9c2489f84ca91f9bbfcafa
parent7f94a5caa251d3d539bbcf75eb97f11824c577ee
Robin Farine writes:

Hi,

Package: BusyBox
Version: 1.0.0-pre10

When an incomplete read or write from/to a local file occurs (i.e.
not an EOF condition), the tftp client prematurely exits. This
problem can be reproduced by slowly piping data to the tftp client
like this:

  (for v in 1 2 3; do echo $v; sleep 1; done) | \
  tftp -p -l - -r output.txt <host>

The output file on the TFTP server will contain "1".

The attached patch provides a possible solution to this problem.

I can reproduce this on ARM sa1110 and ARM xscale boards, both
running Linux-2.6.4 & glibc-2.3.2. Thanks for the wonderful
program!

Robin
networking/tftp.c