kernel: add hardware offload patch for flow tables support
[oweals/openwrt.git] / target / linux / generic / pending-4.14 / 641-netfilter-nf_flow_table-support-hw-offload-through-v.patch
1 From: Felix Fietkau <nbd@nbd.name>
2 Date: Thu, 15 Mar 2018 20:46:31 +0100
3 Subject: [PATCH] netfilter: nf_flow_table: support hw offload through
4  virtual interfaces
5
6 There are hardware offload devices that support offloading VLANs and
7 PPPoE devices. Additionally, it is useful to be able to offload packets
8 routed through bridge interfaces as well.
9 Add support for finding the path to the offload device through these
10 virtual interfaces, while collecting useful parameters for the offload
11 device, like VLAN ID/protocol, PPPoE session and Ethernet MAC address.
12
13 Signed-off-by: Felix Fietkau <nbd@nbd.name>
14 ---
15
16 --- a/include/linux/netdevice.h
17 +++ b/include/linux/netdevice.h
18 @@ -827,6 +827,7 @@ struct xfrmdev_ops {
19  #endif
20  
21  struct flow_offload;
22 +struct flow_offload_hw_path;
23  
24  enum flow_offload_type {
25         FLOW_OFFLOAD_ADD        = 0,
26 @@ -1064,8 +1065,15 @@ enum flow_offload_type {
27   * int (*ndo_bridge_dellink)(struct net_device *dev, struct nlmsghdr *nlh,
28   *                          u16 flags);
29   *
30 + * int (*ndo_flow_offload_check)(struct flow_offload_hw_path *path);
31 + *     For virtual devices like bridges, vlan, and pppoe, fill in the
32 + *     underlying network device that can be used for offloading connections.
33 + *     Return an error if offloading is not supported.
34 + *
35   * int (*ndo_flow_offload)(enum flow_offload_type type,
36 - *                        struct flow_offload *flow);
37 + *                        struct flow_offload *flow,
38 + *                        struct flow_offload_hw_path *src,
39 + *                        struct flow_offload_hw_path *dest);
40   *     Adds/deletes flow entry to/from net device flowtable.
41   *
42   * int (*ndo_change_carrier)(struct net_device *dev, bool new_carrier);
43 @@ -1292,8 +1300,11 @@ struct net_device_ops {
44         int                     (*ndo_bridge_dellink)(struct net_device *dev,
45                                                       struct nlmsghdr *nlh,
46                                                       u16 flags);
47 +       int                     (*ndo_flow_offload_check)(struct flow_offload_hw_path *path);
48         int                     (*ndo_flow_offload)(enum flow_offload_type type,
49 -                                                   struct flow_offload *flow);
50 +                                                   struct flow_offload *flow,
51 +                                                   struct flow_offload_hw_path *src,
52 +                                                   struct flow_offload_hw_path *dest);
53         int                     (*ndo_change_carrier)(struct net_device *dev,
54                                                       bool new_carrier);
55         int                     (*ndo_get_phys_port_id)(struct net_device *dev,
56 --- a/include/net/netfilter/nf_flow_table.h
57 +++ b/include/net/netfilter/nf_flow_table.h
58 @@ -86,6 +86,21 @@ struct flow_offload {
59         };
60  };
61  
62 +#define FLOW_OFFLOAD_PATH_ETHERNET     BIT(0)
63 +#define FLOW_OFFLOAD_PATH_VLAN         BIT(1)
64 +#define FLOW_OFFLOAD_PATH_PPPOE                BIT(2)
65 +
66 +struct flow_offload_hw_path {
67 +       struct net_device *dev;
68 +       u32 flags;
69 +
70 +       u8 eth_src[ETH_ALEN];
71 +       u8 eth_dest[ETH_ALEN];
72 +       u16 vlan_proto;
73 +       u16 vlan_id;
74 +       u16 pppoe_sid;
75 +};
76 +
77  #define NF_FLOW_TIMEOUT (30 * HZ)
78  
79  struct nf_flow_route {
80 --- a/net/netfilter/nf_flow_table_hw.c
81 +++ b/net/netfilter/nf_flow_table_hw.c
82 @@ -19,48 +19,75 @@ struct flow_offload_hw {
83         enum flow_offload_type  type;
84         struct flow_offload     *flow;
85         struct nf_conn          *ct;
86 -       possible_net_t          flow_hw_net;
87 +
88 +       struct flow_offload_hw_path src;
89 +       struct flow_offload_hw_path dest;
90  };
91  
92 -static int do_flow_offload_hw(struct net *net, struct flow_offload *flow,
93 -                             int type)
94 +static void flow_offload_check_ethernet(struct flow_offload_tuple *tuple,
95 +                                       struct flow_offload_hw_path *path)
96  {
97 -       struct net_device *indev;
98 -       int ret, ifindex;
99 +       struct net_device *dev = path->dev;
100 +       struct neighbour *n;
101  
102 -       ifindex = flow->tuplehash[FLOW_OFFLOAD_DIR_ORIGINAL].tuple.iifidx;
103 -       indev = dev_get_by_index(net, ifindex);
104 -       if (WARN_ON(!indev))
105 -               return 0;
106 +       if (dev->type != ARPHRD_ETHER)
107 +               return;
108  
109 -       mutex_lock(&nf_flow_offload_hw_mutex);
110 -       ret = indev->netdev_ops->ndo_flow_offload(type, flow);
111 -       mutex_unlock(&nf_flow_offload_hw_mutex);
112 +       memcpy(path->eth_src, path->dev->dev_addr, ETH_ALEN);
113 +       n = dst_neigh_lookup(tuple->dst_cache, &tuple->src_v4);
114 +       if (!n)
115 +               return;
116  
117 -       dev_put(indev);
118 +       memcpy(path->eth_dest, n->ha, ETH_ALEN);
119 +       path->flags |= FLOW_OFFLOAD_PATH_ETHERNET;
120 +       neigh_release(n);
121 +}
122  
123 -       return ret;
124 +static int flow_offload_check_path(struct net *net,
125 +                                  struct flow_offload_tuple *tuple,
126 +                                  struct flow_offload_hw_path *path)
127 +{
128 +       struct net_device *dev;
129 +
130 +       dev = dev_get_by_index_rcu(net, tuple->iifidx);
131 +       if (!dev)
132 +               return -ENOENT;
133 +
134 +       path->dev = dev;
135 +       flow_offload_check_ethernet(tuple, path);
136 +
137 +       if (dev->netdev_ops->ndo_flow_offload_check)
138 +               return dev->netdev_ops->ndo_flow_offload_check(path);
139 +
140 +       return 0;
141  }
142  
143 -static void flow_offload_hw_work_add(struct flow_offload_hw *offload)
144 +static int do_flow_offload_hw(struct flow_offload_hw *offload)
145  {
146 -       struct net *net;
147 +       struct net_device *src_dev = offload->src.dev;
148 +       struct net_device *dest_dev = offload->dest.dev;
149         int ret;
150  
151 -       if (nf_ct_is_dying(offload->ct))
152 -               return;
153 +       ret = src_dev->netdev_ops->ndo_flow_offload(offload->type,
154 +                                                   offload->flow,
155 +                                                   &offload->src,
156 +                                                   &offload->dest);
157  
158 -       net = read_pnet(&offload->flow_hw_net);
159 -       ret = do_flow_offload_hw(net, offload->flow, FLOW_OFFLOAD_ADD);
160 -       if (ret >= 0)
161 -               offload->flow->flags |= FLOW_OFFLOAD_HW;
162 +       /* restore devices in case the driver mangled them */
163 +       offload->src.dev = src_dev;
164 +       offload->dest.dev = dest_dev;
165 +
166 +       return ret;
167  }
168  
169 -static void flow_offload_hw_work_del(struct flow_offload_hw *offload)
170 +static void flow_offload_hw_free(struct flow_offload_hw *offload)
171  {
172 -       struct net *net = read_pnet(&offload->flow_hw_net);
173 -
174 -       do_flow_offload_hw(net, offload->flow, FLOW_OFFLOAD_DEL);
175 +       dev_put(offload->src.dev);
176 +       dev_put(offload->dest.dev);
177 +       if (offload->ct)
178 +               nf_conntrack_put(&offload->ct->ct_general);
179 +       list_del(&offload->list);
180 +       kfree(offload);
181  }
182  
183  static void flow_offload_hw_work(struct work_struct *work)
184 @@ -73,18 +100,22 @@ static void flow_offload_hw_work(struct
185         spin_unlock_bh(&flow_offload_hw_pending_list_lock);
186  
187         list_for_each_entry_safe(offload, next, &hw_offload_pending, list) {
188 +               mutex_lock(&nf_flow_offload_hw_mutex);
189                 switch (offload->type) {
190                 case FLOW_OFFLOAD_ADD:
191 -                       flow_offload_hw_work_add(offload);
192 +                       if (nf_ct_is_dying(offload->ct))
193 +                               break;
194 +
195 +                       if (do_flow_offload_hw(offload) >= 0)
196 +                               offload->flow->flags |= FLOW_OFFLOAD_HW;
197                         break;
198                 case FLOW_OFFLOAD_DEL:
199 -                       flow_offload_hw_work_del(offload);
200 +                       do_flow_offload_hw(offload);
201                         break;
202                 }
203 -               if (offload->ct)
204 -                       nf_conntrack_put(&offload->ct->ct_general);
205 -               list_del(&offload->list);
206 -               kfree(offload);
207 +               mutex_unlock(&nf_flow_offload_hw_mutex);
208 +
209 +               flow_offload_hw_free(offload);
210         }
211  }
212  
213 @@ -97,20 +128,55 @@ static void flow_offload_queue_work(stru
214         schedule_work(&nf_flow_offload_hw_work);
215  }
216  
217 +static struct flow_offload_hw *
218 +flow_offload_hw_prepare(struct net *net, struct flow_offload *flow)
219 +{
220 +       struct flow_offload_hw_path src = {};
221 +       struct flow_offload_hw_path dest = {};
222 +       struct flow_offload_tuple *tuple;
223 +       struct flow_offload_hw *offload = NULL;
224 +
225 +       rcu_read_lock_bh();
226 +
227 +       tuple = &flow->tuplehash[FLOW_OFFLOAD_DIR_ORIGINAL].tuple;
228 +       if (flow_offload_check_path(net, tuple, &src))
229 +               goto out;
230 +
231 +       tuple = &flow->tuplehash[FLOW_OFFLOAD_DIR_REPLY].tuple;
232 +       if (flow_offload_check_path(net, tuple, &dest))
233 +               goto out;
234 +
235 +       if (!src.dev->netdev_ops->ndo_flow_offload)
236 +               goto out;
237 +
238 +       offload = kzalloc(sizeof(struct flow_offload_hw), GFP_ATOMIC);
239 +       if (!offload)
240 +               goto out;
241 +
242 +       dev_hold(src.dev);
243 +       dev_hold(dest.dev);
244 +       offload->src = src;
245 +       offload->dest = dest;
246 +       offload->flow = flow;
247 +
248 +out:
249 +       rcu_read_unlock_bh();
250 +
251 +       return offload;
252 +}
253 +
254  static void flow_offload_hw_add(struct net *net, struct flow_offload *flow,
255                                 struct nf_conn *ct)
256  {
257         struct flow_offload_hw *offload;
258  
259 -       offload = kmalloc(sizeof(struct flow_offload_hw), GFP_ATOMIC);
260 +       offload = flow_offload_hw_prepare(net, flow);
261         if (!offload)
262                 return;
263  
264         nf_conntrack_get(&ct->ct_general);
265         offload->type = FLOW_OFFLOAD_ADD;
266         offload->ct = ct;
267 -       offload->flow = flow;
268 -       write_pnet(&offload->flow_hw_net, net);
269  
270         flow_offload_queue_work(offload);
271  }
272 @@ -119,14 +185,11 @@ static void flow_offload_hw_del(struct n
273  {
274         struct flow_offload_hw *offload;
275  
276 -       offload = kmalloc(sizeof(struct flow_offload_hw), GFP_ATOMIC);
277 +       offload = flow_offload_hw_prepare(net, flow);
278         if (!offload)
279                 return;
280  
281         offload->type = FLOW_OFFLOAD_DEL;
282 -       offload->ct = NULL;
283 -       offload->flow = flow;
284 -       write_pnet(&offload->flow_hw_net, net);
285  
286         flow_offload_queue_work(offload);
287  }
288 @@ -153,12 +216,8 @@ static void __exit nf_flow_table_hw_modu
289         nf_flow_table_hw_unregister(&flow_offload_hw);
290         cancel_work_sync(&nf_flow_offload_hw_work);
291  
292 -       list_for_each_entry_safe(offload, next, &hw_offload_pending, list) {
293 -               if (offload->ct)
294 -                       nf_conntrack_put(&offload->ct->ct_general);
295 -               list_del(&offload->list);
296 -               kfree(offload);
297 -       }
298 +       list_for_each_entry_safe(offload, next, &hw_offload_pending, list)
299 +               flow_offload_hw_free(offload);
300  }