3 bool "Bit-banged ethernet MII management channel support"
5 config MV88E6352_SWITCH
6 bool "Marvell 88E6352 switch support"
9 bool "Ethernet PHY (physical media interface) support"
12 Enable Ethernet PHY (physical media interface) support.
16 config PHY_ADDR_ENABLE
17 bool "Limit phy address"
18 default y if ARCH_SUNXI
20 Select this if you want to control which phy address is used
25 default 1 if ARCH_SUNXI
28 The address of PHY on MII bus. Usually in range of 0 to 31.
32 bool "Broadcom BCM53xx (RoboSwitch) Ethernet switch PHY support."
34 Enable support for Broadcom BCM53xx (RoboSwitch) Ethernet switches.
35 This currently supports BCM53125 and similar models.
44 hex "Bitmask of PHY ports"
48 config MV88E61XX_SWITCH
49 bool "Marvel MV88E61xx Ethernet switch PHY support."
53 config MV88E61XX_CPU_PORT
56 config MV88E61XX_PHY_PORTS
57 hex "Bitmask of PHY Ports"
59 config MV88E61XX_FIXED_PORTS
60 hex "Bitmask of PHYless serdes Ports"
62 endif # MV88E61XX_SWITCH
65 bool "Generic 10G PHY support"
68 bool "Aquantia Ethernet PHYs support"
71 bool "Atheros Ethernet PHYs support"
74 bool "Broadcom Ethernet PHYs support"
77 bool "Cortina Ethernet PHYs support"
80 bool "Davicom Ethernet PHYs support"
83 bool "LSI TruePHY ET1011C support"
86 bool "LXT971 Ethernet PHY support"
89 bool "Marvell Ethernet PHYs support"
92 bool "Amlogic Meson GXL Internal PHY support"
95 bool "Micrel Ethernet PHYs support"
97 Enable support for the GbE PHYs manufactured by Micrel (now
98 a part of Microchip). This includes drivers for the KSZ804,
99 KSZ8031, KSZ8051, KSZ8081, KSZ8895, KSZ886x, KSZ8721
100 either/or KSZ9021 (see the "Micrel KSZ9021 family support"
101 config option for details), and KSZ9031 (if configured).
105 config PHY_MICREL_KSZ9021
108 select PHY_MICREL_KSZ90X1
110 config PHY_MICREL_KSZ9031
113 select PHY_MICREL_KSZ90X1
115 config PHY_MICREL_KSZ90X1
116 bool "Micrel KSZ90x1 family support"
119 Enable support for the Micrel KSZ9021 and KSZ9031 GbE PHYs. If
120 enabled, the extended register read/write for KSZ90x1 PHYs
121 is supported through the 'mdio' command and any RGMII signal
122 delays configured in the device tree will be applied to the
123 PHY during initialization.
125 This should not be enabled at the same time with PHY_MICREL_KSZ8XXX
126 as the KSZ9021 and KS8721 share the same ID.
128 config PHY_MICREL_KSZ8XXX
129 bool "Micrel KSZ8xxx family support"
130 default y if !PHY_MICREL_KSZ90X1
132 Enable support for the 8000 series GbE PHYs manufactured by Micrel
133 (now a part of Microchip). This includes drivers for the KSZ804,
134 KSZ8031, KSZ8051, KSZ8081, KSZ8895, KSZ886x, and KSZ8721.
136 This should not be enabled at the same time with PHY_MICREL_KSZ90X1
137 as the KSZ9021 and KS8721 share the same ID.
142 bool "Microsemi Corp Ethernet PHYs support"
145 bool "National Semiconductor Ethernet PHYs support"
148 bool "Realtek Ethernet PHYs support"
150 config RTL8211E_PINE64_GIGABIT_FIX
151 bool "Fix gigabit throughput on some Pine64+ models"
152 depends on PHY_REALTEK
154 Configure the Realtek RTL8211E found on some Pine64+ models differently to
155 fix throughput on Gigabit links, turning off all internal delays in the
156 process. The settings that this touches are not documented in the CONFREG
157 section of the RTL8211E datasheet, but come from Realtek by way of the
158 Pine64 engineering team.
160 config RTL8211X_PHY_FORCE_MASTER
161 bool "Ethernet PHY RTL8211x: force 1000BASE-T master mode"
162 depends on PHY_REALTEK
164 Force master mode for 1000BASE-T on RTl8211x PHYs (except for RTL8211F).
165 This can work around link stability and data corruption issues on gigabit
166 links which can occur in slave mode on certain PHYs, e.g. on the
169 Please note that two directly connected devices (i.e. via crossover cable)
170 will not be able to establish a link between each other if they both force
171 master mode. Multiple devices forcing master mode when connected by a
172 network switch do not pose a problem as the switch configures its affected
173 ports into slave mode.
175 This option only affects gigabit links. If you must establish a direct
176 connection between two devices which both force master mode, try forcing
177 the link speed to 100MBit/s.
182 bool "Microchip(SMSC) Ethernet PHYs support"
184 config PHY_TERANETICS
185 bool "Teranetics Ethernet PHYs support"
188 bool "Texas Instruments Ethernet PHYs support"
191 bool "Vitesse Ethernet PHYs support"
194 bool "Xilinx Ethernet PHYs support"
197 bool "Fixed-Link PHY"
200 Fixed PHY is used for having a 'fixed-link' to another MAC with a direct
201 connection (MII, RGMII, ...).
202 There is nothing like autoneogation and so
203 on, the link is always up with fixed speed and fixed duplex-setting.
204 More information: doc/device-tree-bindings/net/fixed-link.txt